Derating At T ≥ 40 °C - Jetter JetMove 3000 User Manual

Hide thumbs Also See for JetMove 3000:
Table of Contents

Advertisement

A.4 Derating at T
If the multi-axis system is operated outside the specified maximum ambient temperature (T
put power of the supply unit must be reduced as a function of the higher ambient temperature; this reduc-
tion will have an effect on the current in the DC link connections. This so-called temperature derating is
used to protect parts in the device against overheating.
Device
JM-3P10 / JM-3P10-C1
JM-3P22 / JM-3P22-C1
Table A.8 Derating at T unom ≥ 40 °C
68
≥ 40 °C
unom
Without derating
up to T
unom
40 °C
INFO
The derating must be applied both to the rated currents and to the overload
currents.
JetMove 3000 Supply Unit
With derating
up to T
T
unom
unom
Derating of the output
55 °C
power by 3.0% per 1 °C
), the out-
unom
Derating for
< T
< T
u
umax
Jetter AG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jm-3p10Jm-3p22Jm-3p10-c1Jm-3p22-c1

Table of Contents