JetMove 3000 Supply Unit
3.9.2 Connection example with external brake resistor
Fig. 3.11 Brake resistor connection with thermal contact (X1)
3.10 24 V DC output (X2 top)
Termi-
Ref.
nal
X2
24 V DC OUT
+24 V
GND
For layout see see Fig. Fig. 3.9, and see Fig. Fig. 3.10.
Table 3.10 Specification 24 V DC output X2 BG 1 and BG 2
NOTE:
The same switch-mode power supply unit is installed in both supply units BG 1 and BG 2. The technical
data are therefore identical.
48
Specification
• 24 V DC
• The sum of the power require-
ment via the busbar and the DC
output X2 must not exceed 470 W
• Cable cross section:
6 mm
maximum
2
(11) Supply unit
(15) External brake resistor JBR
X1 Terminal for brake resistor with
thermal contact (Klixon)
(16) Mounting plate (grounded)
Terminal
+24 V
GND
Installation
X2