A.2 Technical data - Supply unit BG 2
Device
Input, mains side
Mains voltage U
± 10 %, 3 times
M
Continuous current [A
AC RMS
Peak current [A
], typically
AC
Continuous power (depending on mains impedance)
Power loss of rectifier
Mains voltage unbalance
Frequency
Maximum wire cross-section of terminals X12
DC link output
DC link voltage, typical *
Continuous current
Peak current 2 x I
for 1 s; line reactor not required
N
Continuous power P
N
Peak power 2 x P
for 1 s
N
DC link capacitance (only JM-3Pxx)
Maximum permissible DC link capacitance JM-3000 + JM-
3Pxx
1)
Power dissipation P
in interior
N
* load-dependent
Table A.3 Technical data - JM-3000 Supply unit BG 2
NOTICE
64
], typically
DAMAGE TO THE DEVICE DUE TO OVERLOAD IN THE
DC LINK CIRCUIT
IGNORING THESE INSTRUCTIONS COULD RESULT IN DAMAGE
TO MATERIAL
y The maximum overall capacity of the DC link circuit must not exceed
the specified value.
INFO
In the overall axis group, a DC link capacitance of ≥ 100 μF/kW (for 3 x 400
V) or ≥ 170 μF/kW (for 3 x 230 V), referred to the highest rated power that oc-
curs, must be provided. This capacitance is calculated by adding the capaci-
tances of the individual devices. The root mean square of the active power for
a load cycle is defined as the active power.
JetMove 3000 Supply Unit
JM-3P22/JM-3P22-C1
230 V AC
400 V AC
46 A
46 A
92 A
92 A
18.5 kVA
110 W
±3 % maximum
50 ... 60 Hz ± 10 %
(finely stranded, with/without
wire end ferrules)
325 V DC
565 V DC
39 A
39 A
78 A
78 A
12.5 kW
25 kW
840 µF
4,000 µF(3,160 + 840) max.
480 V AC
38 A
76 A
32 kVA
1.5 ... 6 mm²
678 V DC
32 A
64 A
22 kW
44 kW
85 W
Jetter AG