JetMove 3000 Supply Unit
NOTICE
3.8
AC mains connection of 24 V switch-mode PSU
The mains connection X7 supplies the integrated 24 V switch-mode power supply unit.
These 24 V DC are used as control supply voltage for the entire axis group via busbar.
To ensure device safety to EN 61800-5-1, use mains fuses with duty class gG that disconnect the device
from the mains in the event of a fault.
Terminal
X7/L1, L2
X7/L1, L2
Table 3.7 Mains fuse of JM-3000 supply unit
Ter-
Ref.
minal
X7
Line IN AUX
n.c.
Table 3.8 Specification of AC mains terminal X7
NOTE:
The same switch-mode power supply unit is installed in both supply units BG 1 and BG 2. The technical
data are therefore identical.
NOTE:
The supply unit with the order number JM-3Pxx comes without a switch-mode power supply unit. For
further details see Section 5.3.
44
DAMAGE TO THE DEVICE DUE TO INCORRECT OPERATION
OPERATION AT 400/480 V SUPPLY VOLTAGE IS NOT ALLOWED
In the event of a ground fault, the voltage is as twice as high.
Clearances and creepage distances according to EN 61800-5-1
are no longer maintained. These effects can destroy the device.
Designation
JM-3P10 (BG 1)
JM-3P22 (BG 2)
Specification
L2
• 2 x 400 ... 480 V AC
• Approx. 2.5 A current con-
sumption
• Cable cross section:
6 mm
maximum
2
L1
Fuse
2 x 6 A (gG)
2 x 6 A (gG)
Terminal
L2
n.c.
L1
Installation
X7