JetMove 3000 Supply Unit
2

Mechanical installation

2.1

Mounting instructions

NOTICE
Please note:
This device is intended exclusively for installation inside a stationary control cabinet. The control
ƒ
cabinet must at least meet the IP44 degree of protection. When using the safety functions (STO and
SBC) in the servo amplifier, the control cabinet must have a degree of protection of IP54 or higher in
accordance with EN ISO 13849-2.
Do not install the supply unit in areas where it will be exposed to constant shocks. Further information
ƒ
can be found in the appendix.
Maximum pollution degree 2 according to EN 60664-1. For more information on environmental condi-
ƒ
tions see the Appendix.
The best result for an EMC-compliant installation can be achieved with a conductive, well grounded,
ƒ
chromated or galvanized mounting plate. If the mounting plate has been painted, remove the paint
from the contact area! The devices themselves have a blue chromated zinc frame.
NOTE:
When installating the supply unit within a multi-axis system, the operating instructions of the other devices
(servo amplifier, controller etc.) must also be observed.
18
MOISTURE OR FOREIGN OBJECTS CAN DAMAGE THE DEVICE
FAILURE TO AVOID FOREIGN OBJECTS OR MOISTURE FROM
ENTERING THE DEVICE COULD RESULT IN DAMAGE TO THE
DEVICE
Avoid at all costs that
ƒ moisture enters into the device
ƒ drill chips, screws or foreign objects fall into the device.