JetMove 3000 Supply Unit
2.4

Mounting wall-mount devices

Step
Arrange the units on the mounting plate as shown
1
1
.
.
Fig. 2.1.
Align all devices of the multi-axis system in one
line along the upper edge of the device.
Mark off the positions of the mounting holes on the
2
2 .
mounting plate.
Drill the holes into the mounting plate and tap a
thread for each fastening screw.
3
3 .
Mount the supply unit vertically on the mounting
plate and the servo amplifiers in a row.
2.4.1 Dimensions of wall-mount models
JM-3Pxx
Weight [kg]
H (height)
1)
H1
H2
W (width)
D (depth)
T1
A
Lateral distance
C (screws)
All dimensions in mm
Drawing see Figure 2.3 and Figure 2.5
Table 2.1 Dimensions and mounting distances
NOTE:
The supply unit must always be mounted to the left of the servo amplifiers. The most powerful servo
amplifier should be close to the supply unit. With twin-axis and triple-axis servo amplifiers, the total power
counts.
22
Action
BG1
JM-3P10-P1R1 - 2.75 kg
JM-3P10-R1 - 2.6 kg
310
299
6
55
241
222
27.5
Can be lined up without gap
2 x M4
This is necessary to be able to connect the DC link
busbars.
Take into account the bending radii of the connec-
tion cables!
For hole spacing and dimensional drawings see
Table 2.1, Fig. 2.4 and Fig. 2.5
The contact surface must be bare metal and con-
ductive.
BG2
JM-3P22-P1R1 - 5.2 kg
JM-3P22-R1 - 5.0 kg
110
27.5
4 x M4
Mechanical installation