Mounting Coldplate Devices; Dimensions Of Models For Coldplate Mounting - Jetter JetMove 3000 User Manual

Hide thumbs Also See for JetMove 3000:
Table of Contents

Advertisement

Mechanical installation
2.5

Mounting ColdPlate devices

Step
Arrange the units on the mounting plate as shown
1
1
.
.
in Fig. 2.1.
Align all devices of the multi-axis system in one
line along the upper edge of the device.
Mark off the positions of the mounting holes on the
2
2 .
corresponding cooler.
Drill the holes into the cooler and tap a thread for
each fastening screw.
The heat conducting film is already glued onto the
back wall of the ColdPlate devices.
3 .
3
Mount the units vertically and in a row on the
cooler.
Tighten the screws evenly to keep the thermal
resistance as low as possible.
The next steps for electrical installation are de-
scribed in chapter 3.

2.5.1 Dimensions of models for ColdPlate mounting

JM-3Pxx
Weight [kg]
H (height)
H1
H2
W (width)
D (depth)
T1
A
Lateral distance
C (screws)
All dimensions in mm
Drawing see Figure 2.3 and Figure 2.5
Table 2.2 Dimensions and mounting distances of ColdPlate devices
NOTE:
The supply unit must always be mounted to the left of the servo amplifiers. The most powerful servo
amplifier should be close to the supply unit. With twin-axis and triple-axis servo amplifiers, the total power
counts.
Jetter AG
Action
BG1
JM-3P10-C1
2.2 kg|
310
299
6
54.5
188.5
170
27.25
Can be lined up without gap
2 x M4
JetMove 3000 Supply Unit
Comment
This is necessary to be able to connect the DC link
busbars.
For specifications for mounting distances see
Table 2.2.
Take into account the bending radii of the connec-
tion cables!
For hole spacings and dimensional drawings see
Table 2.1.
Ensure that the surface of the cooler is free of drill-
ing chips or other contaminants.
BG2
JM-3P22-C1
4.2 kg|
109
27.25
4 x M4
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jm-3p10Jm-3p22Jm-3p10-c1Jm-3p22-c1

Table of Contents