3.12.1 Specification of cross communication terminal (X3)

Ref.
Terminal
Cross-communication output (RJ10 connector),
X3
XC OUT
internal RS485 network for communication with servo
amplifiers
NOTE:
X3 connections are used exclusively for internal communication between the supply unit and the servo
amplifiers.

3.12.2 Specification of relay terminal - REL output (X5)

Ref.
Terminal
R002NO = Normally
X5
open contact

3.12.3 Specification of "State" terminal (X6)

Ref.
Terminal
RO01NC = NC contact
X6
RO01CO = CO contact
RO01NO = NO contact
TP00 = Test pulse
signal 00
TP01 = Test pulse
X6
signal 01
GND = Ground refer-
ence
Jetter AG
Specification
Specification
RO02CO
RO02NO
Specification
RO01NC
RO01CO
RO01NO
Signal driver outputs for internal
use for testing for short-circuits
and shorts between contacts of
the wiring to the safe inputs of
the servo amplifiers
JetMove 3000 Supply Unit
Details
See
JM-3000 User Manual
Item no. 60880296
Details
Relay contact: 230 V AC, 0.5 A max.
(resistive load),
user-programmable contact
Factory setting = control for main contactor
Details
Relay contact: ≤ 50 V AC, 0.5 A maxi-
mum (resistive load)
user-programmable contact
Factory setting = active in case of fault
See
JM-3000 User Manual