JetMove 3000 Supply Unit
2.2
Mounting clearances
NOTICE
*) The bending radius of the mains cable must be taken into account
Fig. 2.2 Mounting clearances JM-3000
The decisive factor for the clearance below the device is the mains cable of the supply unit:
Bending radius of mains cable up to 3 x 10 mm2 (for BG1) - approx. 48 to 98 mm (depending on
cable type)
Bending radius of mains cable up to 3 x 16 mm2 (for BG2) - approx. 150 to 200 mm (depending on
cable type)
20
DAMAGE TO THE DEVICE DUE TO INCORRECT INSTALLATION
IGNORING THE INSTRUCTION COULD RESULT IN DAMAGE TO
MATERIAL.
The minimum clearances shown in the following figure apply to both
supply units and servo amplifiers.
The clearance above is important to avoid heat accumulation.
The clearances below and in front are important to ensure correct
cable routing.
≥ 130
≥ 200
Mechanical installation
≥ 300
Jetter AG