4.18 Full Learn

Prior to carrying out a Full Learn, ensure that you have a number of representative sample
products available to pass through the detector as part of the process.
The Learn process utilises the currently selected product so ensure that you select the correct
product through the Menus > Change menu before continuing.
To perform a Full Learn for a product, proceed as follows:
1. Select Menus > Learn to display the Learn menu and select the Full option.
2. Press the OK / Enter Key to start the Full Learn process. The name and number of the product
being learnt are displayed.
3. A 'WAIT' message is then displayed.
4. This is followed by a 'PASS PRODUCT' message.
5. When the 'PASS PRODUCT' message is displayed, start to pass products through the detector.
6. A 'Learning' message is then displayed, along with a number which signifies either the time in
seconds remaining to pass products if a Photo-eye is not fitted, or the number of product packs
remaining to be passed if a Photo-eye is fitted.
7. Once the Learn process is finished a 'Learn Complete' message is displayed.
Additional messages may be displayed during the Learn process which are listed and explained
in the Learn Messages section.