If this option is selected, when a contaminated package is detected the reject delay time is
counted down, in order for the package to travel to the reject device, where upon the reject
device state is toggled.
The Reject dwell option will not be displayed for configuration in the Menus >
Service > Options menu as it is not used.
Dwell Extension
l
If this option is selected, when a contaminated product is detected the reject device is
immediately activated, and stays activated for a time equal to the reject dwell time. If a
second reject product is detected before the dwell time has timed out, then the dwell time is
counted down from the beginning again.
The Reject delay option will not be displayed for configuration in the Menus >
Service > Options menu as it is not used.
Reject till accept:
l
If this option is selected, when a contaminated product is detected the delay time is timed out,
at which point the reject device becomes activated. The reject device will then stay activated
until an uncontaminated product reaches the reject point.
The Reject dwell option will not be displayed for configuration in the Menus >
Service > Options menu as it is not used.
Reject Relay
The reject relay can be set to be either normally energised or normally de-energised. For fail safe
applications, the relay state should be normally energised so that if there is a fault in the reject
system the relay will drop out causing rejection of all products.
Reject Timing
Two reject timing options are available for selections as follows:
Product relative
l
If this option is selected, you can set the Reject dwell and delay times to different values for each
product.
Universal
l
If this option is selected, the Reject dwell and delay times set in this menu are initially used for all
products.
Changing the values for one product will then automatically update the values for all other
products and also the values set in this menu.
Reject Confirm
Enable this option if a Reject Confirmation Photo-eye is fitted to your system. This photo-eye is
fitted across the entrance to the reject bin to confirm that the contaminated product has