Auxiliary relay
The following options are available for selection, depending on what function the relay is
providing:
In run (Default)
l
Select this option if you are using the relay to signal that the metal detector is inspecting
product.
Reject
l
Selecting this option provides an additional set of reject activated contacts.
Check debug
l
Select this option to assist with setting up the Pack check feature, enabled in the Rejects Setup
screen.
PV Test
Selecting this option enables the Performance Validation feature for the currently selected
product, using the options selected in the Menus > Set Up > PV Test Set Up menu.
Reverse mode
If this option is selected then the detector will work in reverse by passing 'contaminated'
products and rejecting 'good' products.
This is useful when for example a product contains a metal 'toy' so products that do not contain
the 'toy' are to be rejected.
Note that a Product Registration Photo-eye must be fitted to use this option.
Access Filter
If this option is selected then the Detection Filter option is included for selection in the Menus >
Learn > Set Up menu.