Setting Up The Reject Options - Loma IQ3X Operating Instructions Manual

Metal detection system
Table of Contents

Advertisement

Operating Instructions
4. Navigate to the Menus > Change menu, then use the Navigation Keys
display the Ferrite F product and press the OK / Enter Key
5. Perform a Full Learn whilst moving the end of the ferrite wand with the sample in and out of the
search head; taking care not to put your hand in or get any watches/rings near the search head.
On systems fitted with a Product Registration Photo-eye, block the photo-eye to
register that packs are present.
6. Once a successful Learn has been completed, navigate back to the Menus > Service >
Options menu and de-select the Access Ferrite option.
You have now completed the Ferrite Tune process.

4.15 Setting Up the Reject Options

To set up the reject options, proceed as follows:
1. Select Menus > Service > Reject > Set Up to display the Reject Set Up menu options which are
listed and described below.
2. Use the Navigation Keys
to enable the value to be edited.
3. Use the Navigation Keys
OK / Enter Key
to confirm the selection.
4. Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Reject Set Up menu options available are as follows:
Mode
The following Mode options are provided for selection:
Pulse (only available if a photo-eye is fitted)
l
If this option is selected, when a contaminated package is detected the reject delay time is
counted down, in order for the package to travel from the photo-eye to the reject device,
where-upon the reject is turned on for a time equal to the reject dwell time. Typically, this mode
of reject would be used for air blast or pusher type rejects for the accurate rejection of small
packages at high speed.
Pulse Extension
l
This option provides the same functionality as the Pulse option, except that the dwell time is
extended if a second contaminated product reaches the reject point before the dwell time
from the first contaminated product has timed out. This could typically be used with an air blast
or retracting band reject device, but not a pusher type device. This reject mode is always
available.
Toggle (only available if a photo-eye is fitted)
l
Copyright © Loma Systems
to select it.
to select each option in turn press the OK / Enter Key
to select the required option value and then press the
58
to