Operating Instructions
entered the bin. A system fault is generated if a confirmation signal is not received by the
detector.
Pack Check
Select this option to ensure that packs that are counted onto the detector conveyor are
counted off. This option also helps to ensure that packs that should have been rejected, but did
not enter the reject bin, do not leave the detector conveyor by stopping it. This option only
appears if a Product Registration Photo-eye has been fitted and enabled in the Menus > Service
> Configuration > System menu and the Pack Check Photo eye has been installed.
Bin Full
Enable this option if a bin full sensor has been fitted to your system. This sensor is fitted inside the
bin towards the top. As contaminated products stack up inside the bin, once they break the
sensor beam a system fault is generated to warn the operator that the bin must be emptied.
Double Bag
Select this option to reject products if the length is longer than expected. For example, bags in a
continuous stream may need to be separated prior to being inspected and this separation may
have failed, resulting in a double-bag entering the detector. This option is only available if a
Product Registration Photo-eye has been installed.
In addition to the above, the following option is available for selection in the Menus > Service >
Reject > Control menu:
Disable Rejects
Selecting this option temporarily disables the reject device. This feature is intended for Loma
Service Engineer use only.