ABB RELION 615 Series Applications Manual page 156

Feeder protection and control relay
Hide thumbs Also See for RELION 615 Series:
Table of Contents

Advertisement

Section 3
REF615 standard configurations
OR20
PHIPTOC1_50P-3_PICKUP
B1
B2
DPHHPDOC1_67/50P-1_PICKUP
B3
DPHLPDOC1_67/51P-1_PICKUP
B4
DPHLPDOC2_67/51P-2_PICKUP
B5
NSPTOC1_46-1_PICKUP
B6
NSPTOC2_46-2_PICKUP
B7
DEFHPDEF1_67/50N-1_PICKUP
B8
DEFLPDEF1_67/51N-1_PICKUP
B9
DEFLPDEF2_67/51N-2_PICKUP
B10
EFPADM1_21YN-1_PICKUP
B11
EFPADM2_21YN-2_PICKUP
B12
EFPADM3_21YN-3_PICKUP
WPWDE1_32N-1_PICKUP
B13
WPWDE2_32N-2_PICKUP
B14
WPWDE3_32N-3_PICKUP
B15
INTRPTEF1_67NIEF_PICKUP
B16
B17
EFHPTOC1_50G-1_PICKUP
B18
ROVPTOV1_59G_PICKUP
B19
ROVPTOV2_59N-1_PICKUP
B20
ROVPTOV3_59N-2_PICKUP
O:124|T:2.5|I:9
OR20
B1
PDNSPTOC1_46PD_PICKUP
PHPTOV1_59-1_PICKUP
B2
PHPTOV2_59-2_PICKUP
B3
PHPTOV3_59-3_PICKUP
B4
B5
PSPTUV1_47U-1_PICKUP
B6
NSPTOV1_47-1_PICKUP
B7
PHPTUV1_27-1_PICKUP
B8
PHPTUV2_27-2_PICKUP
B9
PHPTUV3_27-3_PICKUP
B10
T1PTTR1_49F_PICKUP
B11
DPHHPDOC2_67/50P-2_PICKUP
B12
DEFHPDEF2_67/50N-2_PICKUP
B13
B14
B15
B16
B17
B18
B19
B20
O:125|T:2.5|I:10
GUID-C663443E-751F-4608-B8AF-B78EC13414D4 V1 EN
Figure 188:
General pickup and trip signals
150
O
B1
PHIPTOC1_50P-3_TRIP
B2
DPHHPDOC1_67/50P-1_TRIP
B3
DPHLPDOC1_67/51P-1_TRIP
B4
DPHLPDOC2_67/51P-2_TRIP
B5
NSPTOC1_46-1_TRIP
B6
NSPTOC2_46-2_TRIP
B7
DEFHPDEF1_67/50N-1_TRIP
B8
DEFLPDEF1_67/51N-1_TRIP
B9
DEFLPDEF2_67/51N-2_TRIP
B10
EFPADM1_21YN-1_TRIP
B11
EFPADM2_21YN-2_TRIP
EFPADM3_21YN-3_TRIP
B12
WPWDE1_32N-1_TRIP
B13
WPWDE2_32N-2_TRIP
B14
WPWDE3_32N-3_TRIP
B15
B16
INTRPTEF1_67NIEF_TRIP
B17
EFHPTOC1_50G-1_TRIP
B18
ROVPTOV1_59G_TRIP
B19
ROVPTOV2_59N-1_TRIP
B20
ROVPTOV3_59N-2_TRIP
O
PDNSPTOC1_46PD_TRIP
B1
PHPTOV1_59-1_TRIP
B2
B3
PHPTOV2_59-2_TRIP
B4
PHPTOV3_59-3_TRIP
B5
PSPTUV1_47U-1_TRIP
B6
NSPTOV1_47-1_TRIP
B7
PHPTUV1_27-1_TRIP
B8
PHPTUV2_27-2_TRIP
B9
PHPTUV3_27-3_TRIP
B10
T1PTTR1_49F_TRIP
B11
ARCSARC1_AFD-1_TRIP
B12
ARCSARC2_AFD-2_TRIP
B13
ARCSARC3_AFD-3_TRIP
DPHHPDOC2_67/50P-2_TRIP
B14
DEFHPDEF2_67/50N-2_TRIP
B15
B16
B17
B18
B19
B20
The trip signals from the protection functions are connected to the two trip logics
TRPPTRC1_86/94-1 and TRPPTRC2_86/94-2. The output of these trip logic functions
are available at binary outputs X100:PO3 and X100:PO4. Both the trip logic functions are
provided with lockout and latching function, event generation and the trip signal duration
setting. If the lockout operation mode is selected, binary input has been assigned to
RST_LKOUT input of both the trip logic to enable external reset with a push button.
Three other trip logics TRPPTRC3...5_86/94-3...5 are also available if the relay is
ordered with high speed binary outputs options.
OR20
OR6
O
B1
B2
B3
B4
B5
B6
O:128|T:2.5|I:53
OR6
B1
B2
B3
B4
B5
B6
O:129|T:2.5|I:3
O:127|T:2.5|I:6
OR20
O
O:126|T:2.5|I:7
1MAC109016-MB C
TPGAPC1
O
IN1
OUT1
GENERAL_PICKUP_PULSE
IN2
OUT2
GENERAL_TRIP_PULSE
O:130|T:2.5|I:1
O
Application Manual
REF615 ANSI