Tube V9 is removed in all tests until told otherwise. Any DMM with min. 10meg.ohm Input Z, or a scope will work in all tests below. any 100watt or more..
Page 111
Using scope? see R27 connect to other side of it. This is CW mode and uses the LMO mixed with the HET oscillator. Any modern DMM or Scope with 10meg ohms min. input impedance "Z" or better. works. here.
Page 120
As a minimum you will need Y1, Y8, Y9,10 and 11. to complete these steps. For sure the Y1 to 8 that you want to DX on. I'm adding step numbers to all major alignment steps. On my schematic , I put red stars and blue STARs, the red mean factory test points and my blue Stars are my SCOPE test points.
Page 121
or modern DMM or scope or scope this shuts down the finals. V9 is removed THE BANDS WILL BE DEAD IF THE CRYSTAL IS MISSING STEP2 Still in CW mode Step 1, Het OSC. E pin is small coax pin. warning 800vdc present Key means the rear 1/4"...
Page 122
IF the CW crystal is missing this will fail 4v P-P on scope ,tune STEP6 The Dummy load connected ! STEP3 This is final Grid Drive. STEP4 CW KEYED ! CW mode STEP5 V9 is main driver As much as 120v p-p at antenna too. Keep in mind all oscillators must work On 3.5mhz, pin2 V9 I got 10v p-p here or this signal will be wrong, there...
Page 123
STEP7 Y7 is normally missing, mine is. Normally this crystal is missing, STEP9 STEP8 I had to find and buy this crystal...
Page 124
watch the VM meter like a hawk, 0v STEP 10 SKIP NEXT 7 PARAGRAPHS IF BUILT Why is assembly here, oddly Best practice is to Chicken stick all main CAP, before touching wires or pins.
Page 125
STEP 11 3.5000 exactly STEP 11 SKIP THESE 2 Small alum. knob at 2pm on dial. I forgo all this calib., as I have DDS , external VFO now. Use any modern receiver. All are its dead accurate out of the box. dead accurate, for this.