Initial Test - Heathkit SB-401 Assembly Manual

Ssb transmitter
Hide thumbs Also See for SB-401:
Table of Contents

Advertisement

Page 87
HEATHK:I-r®
BAND - 3.5.
Neutralizing
capacitor
- 1/3 meshed from fully
open.
*This is the final adjustment
of this control. No
further
adjustment
required.
FUNC
TION -
TRAN.
METER -
REL
PWR.
Relative Power control - fully clockwise.
LMO -
Any point.
CARRIER NULL control - 1/2 rotation.
DRIVER - Fully counterclockwise.
CARRIER
NULL
capacitor
-1/2
meshed.
FREQ
CONTROL -
UNLOCKED.
SIDEBAND AMPLITUDE BALANCE -
1/2 rotation. *
LEVEL -
0
(fully counterclockwise).
FINAL - 80.
ALC ADJUST - 1/2 rotation.
Set
all controls
and switches
as follows:
ANTI-VOX - fully counterclockwise.
Refer to Figure
1-2 (fold-out from Page 86).
VOX DELA Y - fully counterclockwise.
VOX GAIN - fully clockwise.
BIAS ADJUST -
1/2
rotation.
MODE -
ew.
Before installing
the fuse or tubes, the following
resistance
checks
should be performed.
If the
actual resistance
readings
vary more than ±20%
from
those
listed,
refer
to the In Case
Of
Difficulty section of the Manual on Page 117.
INITIAL TEST

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents