DDMC Analog Input Process Meter / Controller
Display Functions & Messages
The meter displays various functions and messages
during setup, programming, and operation. The
following table shows the main menu functions and
messages in the order they appear in the menu.
Display Functions & Messages
Display
Parameter
Setup
setup
Input
Input
4-20 mA
nmA
0-10 VDC
volt
Dual-scale
d-SCAL
Units
units
Decimal
Dec pt
point
PV1
PV 1
PV2
PV 2
Program
prog
Scale
SCALE
Scale 1
SCAL 1
Scale 2
SCAL 2
Calibrate
Cal
Input 1
Inp 1
Display 1
Dis 1
Input 2
Inp 2
Display 2
Dis 2
Error
Error
Display
dsplay
Display
Line 1
Line 1
Display
Line 2
Line 2
Display
d-Inty
intensity
Relay
RELaY
Relay 1
RLY 1
Action/Setting
Description
Enter Setup menu
Enter Input selection menu
Set meter for 4-20 mA
input
Set meter for ±10 VDC
input
Press Enter to select dual-
scale display for some
level applications (Select
Yes or No)
Select the display
units/tags
Set decimal point
PV1 decimal point (Level)
PV2 decimal point (Level)
Enter the Program menu
Enter the Scale menu
Enter the Scale menu for
PV1
Enter the Scale menu for
PV2
Enter the Calibration menu
Calibrate input 1 signal or
program input 1 value
Program display 1 value
Calibrate input 2 signal or
program input 2 value (up
to 32 points)
Program display 2 value
(up to 32 points)
Error, calibration not
successful, check signal or
programmed value
Enter the Display menu
Press Enter to assign the
Main display parameter
(default: PV)
Press Enter to assign the
small display parameter
(default: engineering units)
Set display intensity level
from 1 to 8
Enter the Relay menu
Relay 1 setup
20
Display Functions & Messages
Display
Parameter
Action/Setting
Description
Set relay 1 action
Action 1
Act 1
Automatic
Set relay for automatic
Auto
reset
Set relay for automatic &
Auto-
A-nman
manual reset any time
manual
Set relay for latching
Latching
LatCH
operation
Set relay for latching
Latching-
Lt-CLr
operation with manual
cleared
reset only after alarm
condition has cleared
Alternate
Set relay for pump
Altern
alternation control
Sampling
Set relay for sampling
Sanmpl
operation
Disable relay and front
Off
OFF
panel status LED (Select
Off to enable Interlock
feature)
Set 1
Program set point 1
Set 1
Program reset point 1
Reset 1
RSt 1
Relays 2-8 setup
Relay 2
RLY 2
Note: Relays 5-8 are
shown, only if expansion
relay module is installed.
Fail-safe
Enter Fail-safe menu
FaiLSF
Set relay 1 fail-safe
Fail-safe 1
FLS 1
operation
On
Enable fail-safe operation
on
Disable fail-safe operation
Off
off
Set relays 2-8 fail-safe
Fail-safe 2
FLS 2
operation
Enter relay Time Delay
Delay
DeLAY
menu
Enter relay 1 time delay
Delay 1
DLY 1
setup
Set relay 1 On time delay
On 1
On 1
Set relay 1 Off time delay
Off 1
OFF 1
Delay 2
Enter relays 2-8 time delay
DLY 2
setup
Loop
Set relay condition if loop
break
break detected
break
Ignore loop break condition
Ignore
ignore
(Processed as a low signal
condition)
Relay goes to alarm
On
On
condition when loop break
is detected
Off
Relay goes to non-alarm
Off
condition when loop break
is detected
Enter the Analog output
Analog
Aout
output
scaling menu