DDMC Analog Input Process Meter / Controller
Factory Defaults & User Settings
The following table shows the factory setting for most
of the programmable parameters on the meter.
Parameter
Display
Input type
Input
Dual-scale feature
d-SCAL
Filter
filter
Bypass
bypass
Function
Functn
Number of points
No Pts
Programming
prog
Input 1
InP 1
Display 1
Dis 1
Input 2
InP 2
Display 2
Dis 2
Decimal point
dd. d dd
Cutoff value
CutofF
Display
Dsplay
assignment
Display Line 1
Line 1
Display Line 2
Line 2
Display intensity
d-Inty
Relay 1 action
Act 1
Relay 1 set point
Set 1
Relay 1 reset point
RSt 1
Relay 2 action
Act 2
Relay 2 set point
Set 2
Relay 2 reset point
RSt 2
Relay 3 action
Act 3
Relay 3 set point
Set 3
Relay 3 reset point
RSt 3
Relay 4 action
Act 4
Relay 4 set point
Set 4
Relay 4 reset point
RSt 4
Fail-safe relay 1
Fls 1
Fail-safe relay 2
Fls 2
Fail-safe relay 3
Fls 3
Fail-safe relay 4
Fls 4
On delay relay 1
On 1
Off delay relay 1
Off 1
On delay relay 2
On 2
Off delay relay 2
Off 2
Default Setting
4-20 mA
No (Single scale)
70
0.2
Linear
2
Scale
4.000 mA
4.000
20.000 mA
20.000
3 places
0.000 (disabled)
PV: Process variable
Eng unit default= mA
6
Automatic
1.000
0.500
Automatic
2.000
1.500
Automatic
3.000
2.500
Automatic
4.000
3.500
Off
Off
Off
Off
0.0 sec
0.0 sec
0.0 sec
0.0 sec
45
Parameter
Display
On delay relay 3
On 3
Off delay relay 3
Off 3
On delay relay 4
On 4
Off delay relay 4
Off 4
Loop break relay 1
ignore
Loop break relay 2
ignore
Loop break relay 3
ignore
Loop break relay 4
ignore
Display 1 analog
Dis 1
out
Output 1 value
Out 1
Display 2 analog
Dis 2
out
Output 2 value
Out 2
Source analog
Source
output
Overrange output
O-rang
Underrange output
u-rang
Loop break output
break
Maximum output
nmAx
Minimum output
nmin
Slave ID (Address)
SlavId
Baud rate
baud
Transmit delay
Tr dly
Parity
Parity
Byte-to-byte
t-byt
timeout
F1 function key
F1
F2 function key
F2
F3 function key
F3
F4 function
F4
Digital input 1
dI 1
Digital input 2
dI 2
Digital input 3
dI 3
Digital input 4
dI 4
Digital output 1
dO 1
Digital output 2
dO 2
Digital output 3
dO 3
Digital output 4
dO 4
Password 1
Pass 1
Password 2
Pass 2
Password 3
Pass 3
Instruction Manual
Default Setting
0.0 sec
0.0 sec
0.0 sec
0.0 sec
Ignore
Ignore
Ignore
Ignore
4.000
4.000 mA
20.000
20.000 mA
Process Variable
21.000 mA
3.000 mA
1.000 mA
23.000 mA
1.000 mA
247
9600
50 ms
Even
010 (0.1 sec)
Reset max & min
Line 1: Max (Hi)
Acknowledge relays
Acknowledge relays
Menu
Right arrow
Up arrow
Enter
Alarm 1
Alarm 2
Alarm 3
Alarm 4
000000 (unlocked)
000000 (unlocked)
000000 (unlocked)