8 Operation

8.8.1 Setting Parameters

8.8 Operating Using Speed Control with an Internally Set Speed

• Internally Set Speed Selection
This function allows speed control operation by externally selecting an input signal from among three servo-
motor speed settings made in advance with parameters in the SERVOPACK. The speed control operations
within the three settings are valid. There is no need for an external speed or pulse generator.
Contact input
8.8.1 Setting Parameters
Parameter
Pn000
Pn301
Pn302
Pn303
Note: The maximum speed of servomotor is used whenever a speed settings for the Pn301 to Pn303
exceed the maximum speed.
8-68
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
/P-CON (/SPD-D)
/P-CL
(/SPD-A)
(/SPD-B)
/N-CL
46
n.
3
Control mode selection: Internally set speed control (contact reference)
Internally Set Speed 1
Setting Range
0 to 10000
Internally Set Speed 2
Setting Range
0 to 10000
Internally Set Speed 3
Setting Range
0 to 10000
SERVOPACK
Internally set speed
CN1
Parameter
41
SPEED1
Pn301
45
SPEED2
Pn302
SPEED3
Pn303
Meaning
Setting Unit
Factory Setting
-1
1 min
Setting Unit
Factory Setting
-1
1 min
Setting Unit
Factory Setting
-1
1 min
Servomotor
Speed
reference
M
Speed
Setting Validation
100
Immediately
Speed
Setting Validation
200
Immediately
Speed
Setting Validation
300
Immediately