Cables For Analog Monitor - YASKAWA E-II Series User Manual

Ac servo drives
Hide thumbs Also See for E-II Series:
Table of Contents

Advertisement

5.5.3 Cables for Analog Monitor

(1) Cable Type: JZSP-CA01 (DE9404559)
Connect the specified cables to CN5 connector for monitoring the analog monitor signals. For details, refer to
9.5 Analog Monitor.
WARNING
5
May cause
electric shock.
Disconnect all power
and wait 5 min.
before servicing.
Use proper
grounding techniques.
Note: Specify the cable type either JZSP-CA01 or DE9404559 when ordering the cable for analog moni-
tor.
(2) Dimensional Drawing
Socket: DF11-4DS-2C ∗
Connector: DF11-2428SCF ∗
1000
* Manufactured by Hirose Electric Corporation.
(3) Specifications
Pin No.
Cable Color
Red
1
White
2
Black (2 cables) GND (0 V)
3 and 4
Note: The above monitoring items are the factory settings. The monitoring items can be changed by set-
ting the parameter Pn003. Refer to 9.5 Analog Monitor.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Cable for Analog Monitor
3
1
+20
mm
-0
Viewed from the cable
Signal
Analog Monitor 2
Analog Monitor 1
Black
Black
4
2
White
Red
Monitoring Item
-1
Motor speed: 1V/1000 min
Torque reference: 1V/100% rated torque
5.5 Peripheral Devices
5
5-15