11.4 Parameter Recording Table

Use the following table for recording parameters.
Note: Setting validation ("immediately" or "after restart") for Pn10B differs depending on the digit. The digits vali-
dated after restart are underlined in "Factory Setting" column.
Parameter
Factory
No.
Setting
Pn000
0000
Pn001
0000
Pn002
0000
Pn003
0002
Pn004
0000
Pn005
0000
Pn100
40 Hz
Pn101
20.00 ms
Pn102
40 /s
Pn103
0%
Pn104
40 Hz
Pn105
20.00 ms
Pn106
40 /s
Pn107
-1
0 min
Pn108
7 reference
units
Pn109
0%
Pn10A
0.00 ms
Pn10B
0000
Pn10C
200%
Pn10D
-1
0 min
Pn10E
-1
0 min
/s
Pn10F
0 reference
units
Pn110
0012
Pn111
100
Pn112
100%
Pn113
1000
Pn114
200
Pn115
32
Pn116
16
Pn117
100%
Pn118
100%
Pn119
50 /s
Pn11A
1000%
Pn11B
50 Hz
Pn11C
70 Hz
Pn11D
100%
Pn11E
100%
Pn11F
0 ms
Pn120
0 ms
Pn121
50 Hz
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

11.4 Parameter Recording Table

Name
Function Selection Basic Switches
Function Selection Application
Switches 1
Function Selection Application
Switches 2
Function Selection Application
Switches 3
Reserved (Do not change)
Reserved (Do not change)
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Moment of Inertia Ratio
2nd Speed Loop Gain
2nd Loop Integral Time Constant
2nd Position Loop Gain
Bias
Bias Width Addition
Feed-forward
Feed-forward Filter Time Constant
Gain-related Application Switches
Mode Switch Torque Reference
Mode Switch Speed Reference
Mode Switch Acceleration
Mode Switch Error Pulse
Online Autotuning Switches
Speed Feedback Compensation
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Reserved (Do not change)
Setting
Validation
After restart
After restart
After restart
After restart
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
After restart
/Immediately
Immediately
Immediately
Immediately
Immediately
After restart
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
11
Immediately
11-29