8 Operation

8.5.1 Setting Parameters

8.5 Operating Using Speed Control with Analog Reference

8.5.1 Setting Parameters

Pn000
Pn300
Sets the analog voltage level for the speed reference (V-REF) necessary to operate the
servomotor at the rated speed.
EXAMPLE
Pn300=600: 6-V input is equivalent to the rated speed of the servomotor
Pn300=1000: 10-V input is equivalent to the rated speed of the servomotor.
Pn300=200: 2-V input is equivalent to the rated speed of the servomotor.
8-38
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Parameter
n.
0
Control mode selection: Speed control (analog reference) (factory setting)
Speed Reference Input Gain
Setting Range
1.50 to 3000
(150 to 30.00 V/rated speed)
(factory setting).
Description
Setting Unit
Factory Setting
0.01 V/Rated
600
speed
(6 V/rated speed)
Speed
Position
Torque
Setting Validation
Immediately
Reference
Speed
Set this
-1
(min )
slope.
Reference
Voltage (V)