Configuring the DeviceMaster in TIA Portal

IP Address Assignment

70 - Configuring the DeviceMaster in TIA Portal
DeviceMaster UP DB9M 2-Port 2E (PNIO-2302)
DeviceMaster UP 2-Port 2E (PNIO-2402)
DeviceMaster UP 4-Port
DeviceMaster PNIO-2304
2. To connect the device to PLC, click the link on the device and select
PLC_1.PROFINET interface_1 from the pop-up menu, as shown in this screen
shot.
A valid IP address and a device name are required to establish a connection
(Application Relationship) between a DeviceMaster gateway and an IO controller.
The next two subsections describe various methods to assign IP address and
device name to the DeviceMaster.
The DeviceMaster Industrial Gateway gateways supports three methods for IP
address assignment according to GSDML Specification V2.32.
LOCAL - A device specific method for IP address assignment. See
an IP Address Statically
DHCP - The Dynamic Host Configuration Protocol for IP address assignment.
See
Assigning an IP Address via DHCP
DCP - IP address assignment via Discovery and basic Configuration Protocol
(DCP). See
Assigning an IP Address via IO Controller
information.
Note: The DeviceMaster's default IP address is 192.168.250.250 and the default
subnet mask is 255.255.0.0. You may need to change your laptop or PC IP
address range to access the web interface or you can use PortVision DX to
change the IP address without changing your settings. Refer to
the DeviceMaster for Configuration
program the IP address.
Description
on Page 71 for more information.
on Page 73 for more information.
on Page 23 to install PortVision DX and