Status LED Behavior
Configuring IO Modules
Inserting IO
Modules and
Submodules
DeviceMaster PNIO | UP User Guide: 2000639 Rev. A
•
Verify that the gateway has a valid device name. See
on Page 75 for assigning device name.
•
Make sure there are no other devices on the same network using the same IP
address or device name.
•
Make sure the matching device name is configured in TIA Portal project.
•
Make sure there is no other IO controller that is having or trying to establish a
connection with the gateway.
•
Go to Diagnostics | System Log web page, look for any possible error messages.
The DeviceMaster has one Status (or PWR, depending on the model) LED.
Status or PWR
LED
Blinks every 10
No PLC connection.
seconds
On (solid)
One or more PLC connections have been established.
Flashing
•
•
IO modules are used to exchange input and output data with serial devices and
Ethernet devices. The DeviceMaster gateway has two categories of IO modules:
•
Serial Port Module – for accessing serial devices
•
Ethernet Device Module – for accessing Ethernet devices
1. Double-click the DeviceMaster module in the Network view to open the Device
overview window.
2. From the Catalog | Module, select the Serial or Ethernet module and drag it
into one of the highlighted slots in the Device overview window.
•
Slot 1..N are reserved for serial ports, where N is the number of available
serial ports. Slot 1 for serial port 1, Slot 2 for serial port 2, so on and so forth.
•
Slot N+1 and N+2 are reserved for Ethernet devices. The number of
Configuring the DeviceMaster in TIA Portal
Description
LED flashing mode is enabled.
Error detected or diagnostics information available.
Configuring the DeviceMaster in TIA Portal - 79
Device Name Assignment