Ethernet; Trunking - 3Com 4007 Release Note

3com 4007: release note
Hide thumbs Also See for 4007:
Table of Contents

Advertisement

Because the 64-bit counters in the ifXTable are read-only counters,
you cannot reset them. Attempting to do so results in no response
from the SNMP agent, and the values are not set.
Through SNMP the object a3ComSysEthernetPortRequestedPortMode
can be set to values out of range for the port, only use the values that
are for 10 or 100. (30022)

Ethernet

The following Ethernet statistics are not reset after the
baseline set
rxPeakFrameRate
txPeakFrameRate
rxPeakByteRate
txPeakByteRate
TCMP Trunk Statistics
The
ethernet summary
show a portType of 1000BaseSX(SC) for the 1000BASE-LX Gigabit
Ethernet (GEN) Interface module (Model Number 3CB9LG2SC).
(29689)
If you disable an Ethernet port on the switch fabric module with the
ethernet portState disable
port, the bridge state for the port remains down. The system does not
forward network traffic on that port. You must reset the switch fabric
module from the EME command line interface with the
command to re enable the bridge state and allow network traffic to
be forwarded on that port.
If a bridging loop exists on a switching module or switch fabric
module, output from the
30 minutes to display. (30080)
These TCMP trunk statistics in the

Trunking

are not reset after you enter the
rxFrames, rxHellos, txFrames, txHellos, rxBadVersion, rxBadType,
rxSameTrunkld, rxOverflow
When you add ports to an existing trunk, and change the port mode
in the same modify operation, you need to reset the module and
modify the trunk twice to add the additional ports to the trunk. The
port mode is updated after the first reset operation. You can add a
Known Problems for Release 3.0.5
command:
and
ethernet detail
command, and later re enable that
ethernet detail
bridge trunk detail display
module baseline set
module
displays incorrectly
reset module
command can take up to
command:
45