SERVICE AS REQUIRED

1. Checking brake pad

WARNING
To avoid serious injury or death:
• The machine can fall or slip from an unsafe
device or supports.
• Use a safe lifting device rated for the load to be
lifted.
• Lower the vehicle onto jack stands and block
the wheels before servicing. (See JACK-UP
POINT on page 54.)
1. Park the vehicle on a firm, flat and level surface.
2. Raise the vehicle with a proper jack and lower
onto jack stands or other stable supports. Block
the wheels remaining on the ground to prevent the
vehicle from moving.
3. Remove the wheel bolts and the tires.
(1) Wheel bolts
4. Check the brake pads for wear or damage.
Check the pad's thickness:
Minimum thickness should be 1 mm (3/64 inch). If
below this or pad material is damaged, contact your
local KUBOTA Dealer.
(1) Brake pad
5. Reinstall the tires with the valve stem to the outside.
78
6. Tighten the wheel bolts evenly in alternating
sequence until snug.
7. Repeat the same procedure for remaining 3 tires.
8. Lower the vehicle completely to the ground.
9. Tighten the wheel bolts from 108.4 to 121.9 N⋅m
(80 to 90 ft⋅lbs).

2. Adjusting parking brake

For proper adjusting of the parking brake, consult your
local KUBOTA Dealer.

3. Replacing fuse

The vehicle electrical system is protected from potential
damage by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
If any of the fuses should blow, replace with a new one
of the same capacity.
WARNING
To avoid serious injury or death:
• Allow the engine to cool down sufficiently until
the ECU cooling fan stops.
IMPORTANT :
• Before replacing a blown fuse, determine why
the fuse blew and make any necessary repairs.
Failure to follow this procedure may result in
serious damage to the vehicle electrical system.
Consult your local KUBOTA Dealer for specific
information dealing with electrical problems.
Replacement procedure
1. Disconnect the negative cable of the battery.
2. Remove the cover and the fuse box cover.
3. Pull out the blown fuse using fuse puller in the fuse
box.
4. Insert a new fuse with the same amperage into the
fuse box.
5. Install the fuse box cover.
6. Connect the negative battery cable.