Modes Of Operation (Obj. 6060H)]; [Modes Of Operation (Obj. 6060H: 00H)] - Mitsubishi Electric Melservo J5 Series User Manual

Hide thumbs Also See for Melservo J5 Series:
Table of Contents

Advertisement

9.5

[Modes of operation (Obj. 6060h)]

[Modes of operation (Obj. 6060h: 00h)]

Data Type
Access
I8
RW
Description
Set a control mode.
Setting value
Description
0
No mode change/No mode assigned
*1
1
Profile position mode (pp)
2
*1
3
Profile velocity mode (pv)
*1
4
Profile torque mode (tq)
5
6
Homing mode (hm)
7
8
Cyclic synchronous position mode (csp)
9
Cyclic synchronous velocity mode (csv)
10
Cyclic synchronous torque mode (cst)
*2
-104
Continuous operation to torque control mode (ct)
*1 Available on servo amplifiers with firmware version A5 or later.
*2 Available on servo amplifiers with firmware version B0 or later.
9 PDS Control Objects
84
9.5 [Modes of operation (Obj. 6060h)]
Mapping
Default
RXMAP
0
Range
Units
Refer to the
following.
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-gMelservo mr-j5w-gMelservo-jet mr-jet g seriesMelservo-j5 seriesMelservo mr-j5-g seriesMelservo mr-j5w-g series

Table of Contents