16.7
[Touch probe 1 positive edge (Obj. 60BAh)]
[Touch probe 1 positive edge (Obj. 60BAh: 00h)]
Data Type
Access
I32
RO
Description
The position latched at the rising edge of touch probe 1 is returned.
When the touch probe function is disabled or when the function is not available for the servo amplifier used, "0" is returned.
16.8
[Touch probe 1 negative edge (Obj. 60BBh)]
[Touch probe 1 negative edge (Obj. 60BBh: 00h)]
Data Type
Access
I32
RO
Description
The position latched at the falling edge of touch probe 1 is returned.
When the touch probe function is disabled or when the function is not available for the servo amplifier used, "0" is returned.
16.9
[Touch probe 2 positive edge (Obj. 60BCh)]
[Touch probe 2 positive edge (Obj. 60BCh: 00h)]
Data Type
Access
I32
RO
Description
The position latched at the rising edge of touch probe 2 is returned.
When the touch probe function is disabled or when the function is not available for the servo amplifier used, "0" is returned.
16.10
[Touch probe 2 negative edge (Obj. 60BDh)]
[Touch probe 2 negative edge (Obj. 60BDh: 00h)]
Data Type
Access
I32
RO
Description
The position latched at the falling edge of touch probe 2 is returned.
When the touch probe function is disabled or when the function is not available for the servo amplifier used, "0" is returned.
Mapping
Default
TXMAP
0
Mapping
Default
TXMAP
0
Mapping
Default
TXMAP
0
Mapping
Default
TXMAP
0
Range
Units
-2147483648 to
pos units
2147483647
Range
Units
-2147483648 to
pos units
2147483647
Range
Units
-2147483648 to
pos units
2147483647
Range
Units
-2147483648 to
pos units
2147483647
16 Touch Probe Function Objects
16.7 [Touch probe 1 positive edge (Obj. 60BAh)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
113
16