1St Pdo Config (Obj. 1C00H)]; [1St Pdo Config (Obj. 1C00H: 00H)]; [Pdo Assignment (Obj. 1C00H: 01H)]; [Pdo Enable (Obj. 1C00H: 02H)] - Mitsubishi Electric Melservo J5 Series User Manual

Hide thumbs Also See for Melservo J5 Series:
Table of Contents

Advertisement

3.5

[1st PDO Config (Obj. 1C00h)]

[1st PDO Config (Obj. 1C00h: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Indexes (= 4) is returned.

[PDO Assignment (Obj. 1C00h: 01h)]

Data Type
Access
U16
RW
Description
Set the addresses of RPDO and TPDO (1600h to 1601h, 1A00h to 1A01h) to be used in communication.

[PDO Enable (Obj. 1C00h: 02h)]

Data Type
Access
U16
RW
Description
Enable/disable the PDO set in [PDO Assignment].
0: PDO disabled
1: PDO enabled

[Error Handling (Obj. 1C00h: 03h)]

Data Type
Access
U16
RW
Description
Perform the setting for the detection of RPDO receive errors. This object is available when an object set in [PDO Assignment]
is mapped to RPDO.
0: Receive error is not detected.
1: Receive error is detected.
2: Error detection starts after receipt of the initial PDO.
Mapping
Default
Impossible
04h
Mapping
Default
Impossible
1600h
Mapping
Default
Impossible
0001h
Mapping
Default
Impossible
0001h
Range
Units
04h (fixed)
Range
Units
0000h to FFFFh
Range
Units
0000h to 0001h
Range
Units
0000h to 0002h
3.5 [1st PDO Config (Obj. 1C00h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
PDO mapping
Save
Parameter
Impossible
Save
Parameter
Impossible
3 PDO Mapping Objects
3
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-gMelservo mr-j5w-gMelservo-jet mr-jet g seriesMelservo-j5 seriesMelservo mr-j5-g seriesMelservo mr-j5w-g series