Quick Stop Option Code (Obj. 605Ah)]; [Quick Stop Option Code (Obj. 605Ah: 00H)] - Mitsubishi Electric Melservo J5 Series User Manual

Hide thumbs Also See for Melservo J5 Series:
Table of Contents

Advertisement

9.3

[Quick stop option code (Obj. 605Ah)]

[Quick stop option code (Obj. 605Ah: 00h)]

Data Type
Access
I16
RW
Description
Set how to decelerate the servo motor to a stop at Quick Stop reception.
Setting value
Description
0 (not supported)
1 (not supported)
2
In the cyclic synchronous positioning/velocity mode (csp/csv), profile positioning/velocity mode (pp/pv), and homing mode (hm), the
servo motor decelerates to a stop with [Quick stop deceleration (Obj. 6085h)] and the state shifts to "Switch On Disabled".
In the cyclic synchronous torque mode (cst), the profile torque mode (tq), and the continuous operation to torque control mode (ct), the
state immediately shifts to "Switch On Disabled" and the servo motor stops with the dynamic brake.
3 (not supported)
4 (not supported)
5 (not supported)
6 (not supported)
7 (not supported)
8 (not supported)
9 PDS Control Objects
82
9.3 [Quick stop option code (Obj. 605Ah)]
Mapping
Default
Impossible
2
Range
Units
2 (fixed)
Save
Parameter
Possible
[Pr. PT68.0]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-gMelservo mr-j5w-gMelservo-jet mr-jet g seriesMelservo-j5 seriesMelservo mr-j5-g seriesMelservo mr-j5w-g series

Table of Contents