Verifying Site Requirements; Space Requirements; Ac Input Electrical Requirements - Nortel Versalar 15000 Installing And Maintaining

Switch router
Hide thumbs Also See for Versalar 15000:
Table of Contents

Advertisement

Verifying Site Requirements

Ensure that the installation site meets the space, electrical, and environmental
requirements listed in this section. See Appendix A, "Technical Specifications,"
for more information.

Space Requirements

The installation site must provide sufficient free space around the Versalar 15000
to ensure proper ventilation and access for servicing
Table 2-3.
Width
19 in. (48.2 cm)

AC Input Electrical Requirements

If you have purchased the AC power option, the installation site must meet the
following electrical requirements for AC power
Table 2-4.
Input Voltage
180-264 volts (V)
50-60 hertz (Hz), +/-3%
308684-B Rev 00
Space Requirements
Minimum Depth
22 in. (55.8 cm)
Electrical Requirements for AC Model (23-inch chassis)
Maximum Input Current
14 amperes (A) maximum at
180 VAC for each input
(2 inputs per power unit)
Installing the Versalar 15000
(Table
2-3).
Depth for Servicing
46.2 in. (1 m 17.5 cm)
(Table
2-4).
Maximum System Power
2000 watts (w)
2-7

Advertisement

Table of Contents
loading

Table of Contents