Spray Control Manifold Assembly (Serial Number Above 315000000)
1
2
6
8
7
10
5
4
FRONT
RIGHT
1. Mounting plate
2. Flange nut (2)
3. Flange nut (6)
4. Hose (from spray pump)
5. Hose clamp (5)
6. Elbow fitting
7. Clamp (11)
8. Gasket (11)
9. Fork (6)
10. Pressure filter assembly
11. Hex head screw (2)
12. Straight fitting (2)
The spray control manifold assembly includes a spray
product filter, the rate control valve, the agitation valve
with bypass valve, the master boom valve with bypass
valve, and the agitation throttle valve.
Spray System
3
11
12
5
13
13. Hose (to tank)
14. Valve actuator − regulating
15. Valve actuator − On/Off
16. Adapter
17. Agitation throttle valve
18. Hose (to agitation nozzles)
19. Threaded adapter
20. Elbow fitting
21. Hose (to flowmeter)
22. O−ring (6)
23. Cap (3)
9
23
8
8
24
7
30
27
34
26
23
25
16
14
8
7
17
22
9
12
5
18
Figure 12
IMPORTANT: Each valve actuator has an internal
circuit breaker to protect the actuator motor. The
circuit breaker should reset in 20 seconds after
power to the actuator is removed.
Page 6 − 24
5
7
32
8
23
9
7
29
24
8
8
31
28
19
15
5
20
Thread
Sealant
24. Cap (2)
25. Rate valve
26. Agitation valve
27. Agitation bypass valve
28. Master boom valve
29. Master boom bypass valve
30. Flange head screw (6)
31. Actuator fork (3)
32. Hose adapter