Code
Type
1000
Error
1001
Error
1002
Error
1004
Error
1005
Error
1006
Error
1007
Error
116
Table of software messages
Possible causes
Sewing motor error:
• Encoder plug
(Sub-D, 9-pin) not connected
or defective
• Encoder defective
Sewing motor error:
• Sewing motor plug not
connected or defective
Sewing motor insulation error
Sewing motor error:
• Incorrect direction of rotation
Sewing motor current error:
• Sewing motor blocked
• Encoder cable not
connected or defective
• Encoder defective
Sewing motor error:
• Max. speed exceeded
• Sewing motor cable defective
• Sewing motor defective
Error in the reference run
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
Troubleshooting
Remedial action
• Check the connection of the
encoder cable and replace, if
necessary
• Check the connection of the
sewing motor cable
• Test sewing motor phases
(R = 2.8Ω, high impedance to
PE)
• Replace the encoder
• Replace the sewing motor
• Replace the controller
• Check motor phase and PE for
low-impedance connection
• Replace the encoder
• Replace the sewing motor
• Replace the encoder
• Check plug assignment and
change, if necessary
• Check wiring in machine distribu-
tor and change it, if necessary
• Test motor phases and check for
correct value
• Remove the blockage
• Check the encoder cable and
replace, if necessary
• Replace the sewing motor
• Switch the machine off and
on again
• Replace the encoder
• Perform reset
• Replace the sewing motor
• Contact customer service
• Replace the encoder
• Eliminate stiff movement in the
machine