68
Fig. 38: Other program parameters in operating mode EDIT
Parameter
Stitch Condensing at Start Stitch condensing at seam
Stitch Condensing at End
Thread Trimmer
Thread Tension at Hook
Adjust Bottom Fullness
in %
Adjust Flat Sewing in %
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
Settings via software
Meaning
beginning
on (= 1) or off (= 0)
Stitch condensing at seam
end
on (= 1) or off (= 0)
Thread trimmer
on (= 1) or off (= 0)
Looper thread tension
Fullness correction
parameter bottom (%)
Flat sewing correction,
only when sewing without
fullness (%)
Value range
0 – 1
0 – 1
0 – 1
1 – 99
-50 – 50
0 – 50