Settings via software
Correcting the fullness before the seam
1. Press the pedal to position 0.
2. Change the fullness correction using the buttons + F% or - F%.
3. Press the pedal forward and sew.
The changed fullness value is applied and displayed.
Correcting the fullness during the seam
1. Press the pedal to position 0.
2. Use the button
to adjust the fullness.
3. Press the pedal forward and sew.
The changed fullness value is applied and displayed.
Changing parameters during the seam
1. Press the pedal to position 0.
2. Change the desired parameter on the control panel.
3. Press the pedal forward and sew.
The seam will be sewn using the altered parameter value.
Canceling sewing program
1. Press the pedal to position -2.
The sewing program is canceled.
62