Type
2253
Error
2255
Error
2256
Error
2262
Error
2271
Error
2272
Error
2273
Error
2274
Error
2275
Error
122
Possible causes
Excess voltage
Y-axis stepper motor
overload (I²T):
• Stepper motor not moving
freely or blocked
• Stepper motor defective
• Controller defective
Y-axis stepper motor:
• Stepper motor not moving
freely
• Stepper motor defective
• Controller defective
Y-axis stepper motor distur-
bance (IDMA auto increment)
Watchdog
Stepper motor overvoltage:
• Stepper motor card defective
Y-axis stepper motor error
Software error
Magnet wheel search
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
Troubleshooting
Remedial action
• Check the mains voltage
• Remove the blockage or the
cause of the stiff movement
• Replace the stepper motor
• Replace the controller
• Correct the cause of not moving
freely
• Replace the stepper motor
• Replace the controller
• Switch the machine off and on
again
• Switch the machine off and on
again
• Performing a software update
• Contact Customer Service
• Replace the controller
• Check the connection
• Test stepper motor phases
(R = 2.8Ω, high impedance to
PE)
• Replace the encoder
• Replace the stepper motor
• Replace the controller
• Perform reset
• Performing a software update
• Contact Customer Service
• Check the connection
• Test stepper motor phases
(R = 2.8Ω, high impedance to
PE)
• Replace the encoder
• Replace the stepper motor
• Replace the controller