DURKOPP ADLER 610-10 Operating Instructions Manual page 132

Hide thumbs Also See for 610-10:
Table of Contents

Advertisement

Code
Type
3011
Error
3012
Error
3020
Error
3021
Error
3022
Error
3030
Error
3104
Warning
4440
Error
4459
6000
Error
6299
6351
Error
6354
6360
Warning
130
Possible causes
Controller: 100 V voltage error
Controller: 100 V voltage error
(I²T)
Short circuit in 24 V input or
output
Short circuit in 24 V input or
output
Short circuit in 24 V input or
output (I²T)
Sewing motor phase error
• Pedal not in rest position
• Setpoint device defective
OP3000 control panel:
Internal error
Internal error
Controller defective (I²C)
Data on machine ID not
admissable
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
Troubleshooting
Remedial action
• Check the connections
• Replace the controller
• Switch the machine off and on
again
• Check the connections
• Replace the controller
• Check the connections
• Replace the controller
• Check the connections
• Replace the controller
• Switch the machine off and on
again
• Check the connections
• Replace the controller
• Test sewing motor phases
(R = 2.8Ω, high impedance to
PE)
• Replace the encoder
• Replace the sewing motor
• Replace the controller
• Do not press the pedal when
starting up the machine
• Replace the setpoint device
• Switch the machine off and on
again
• Performing a software update
• Replace the control panel
• Switch the machine off and on
again
• Performing a software update
• Contact Customer Service
• Replace the controller
• Replace the controller

Advertisement

Table of Contents
loading

This manual is also suitable for:

630-10

Table of Contents