Description:
In certain applications, such as ones where the detector is subjected to a high degree of vibration, the
detector may not choose the optimum calibration setting for dry products during a calibration cycle.
In cases such as these it may be necessary to set this setting to "YES", so that the detector is forced to
work in the Dry mode (see Working Mode of Detection in this section).
Press the [ENTER] key, and then the [ ] or [ ] keys to adjust the setting.
Scope:
YES or NO.
Default:
NO.
Note:
For pharmaceutical pill detectors this should be set to YES, unless the pill is known to have some sort
of conductive additive such as iron.
16

DRY PRODUCT

*DRY PRODUCT YES
SETUP
CALIBRATE
I S C
ENTER
RESULTS
RUN DETECT
CALIBRATE
SYSTEM FAULT
RUN ERROR