13.2.3.2

DC link connection

Table 13-7
DC link rectifier adapter – description of the terminals
Terminal
DCP
DCN
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
Function
DC link positive
DC link negative
Technical specifications
Supply voltage:
720 V-VDE/600 V-UL
Direct supply 4 – 10 mm²
Current carrying capacity: 36 A
connection cross-section: 4 – 10 mm²
Stripped length: 11 mm
Direct supply 35 – 95 mm²
Current carrying capacity: 200 A
connection cross-section: 35 – 95 mm²
Stripped length: 27 mm