X22 Terminals: Smart Line Module; X24 24 V Terminal Adapter - Siemens SINAMICS S120 Equipment Manual

Booksize cold-plate power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Smart Line Modules (5 kW and 10 kW) with cold plate
7.3 Interface description
7.3.5

X22 terminals: smart line module

Table 7-3
Terminal block X22
Terminal
1
2
3
4
Max. connectable cross-section: 1.5 mm
Type: Screw terminal 1 (see Connection Engineering section)
7.3.6

X24 24 V terminal adapter

Table 7-4
Terminal block X24
Terminal
+
M
The 24 V terminal adapter is supplied as standard
Max. connectable cross-section: 6 mm
168
Designation
24 V power supply
DI: Disable Regeneration
DI: Reset
Ground
2
Designation
24 V power supply
Ground
2
Technical specifications
Electronics power supply for controlling digital inputs
X22.2 and 3.
Deactivate feedback (high active).
No power is supplied back to the network from the DC
link. The regenerative energy of the motors may have
to be reduced using a combination of the Braking
Module and braking resistor.
Reset faults (positive edge)
Electronics ground
Technical specifications
24 V DC supply voltage
Electronics ground
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4