Residual risks of power drive systems
When carrying out a risk assessment of the machine in accordance with the EU Machinery
Directive, the machine manufacturer must consider the following residual risks associated
with the control and drive components of a power drive system (PDS).
1. Unintentional movements of driven machine components during commissioning,
2. Exceptional temperatures as well as emissions of light, noise, particles, or gas caused by,
3. Hazardous shock voltages caused by, for example:
4. Electrical, magnetic, and electromagnetic fields that can pose a risk to people with a
5. Emission of pollutants if components or packaging are not disposed of properly.
An assessment of the residual risks of PDS components (see points 1 to 5 above)
established that these risks do not exceed the specified limit values (risk priority number to
EN 60812 RPZ ≤ 125).
For more information about residual risks of the power drive system components, see the
relevant chapters in the technical user documentation.
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
operation, maintenance, and repairs caused by, for example:
– Hardware defects and/or software errors in the sensors, controllers, actuators, and
connection technology
– Response times of the controller and drive
– Operating and/or ambient conditions not within the scope of the specification
– Parameterization, programming, cabling, and installation errors
– Use of radio devices / cellular phones in the immediate vicinity of the controller
– External influences / damage
for example:
– Component malfunctions
– Software errors
– Operating and/or ambient conditions not within the scope of the specification
– External influences / damage
– Component malfunctions
– Influence of electrostatic charging
– Induction of voltages in moving motors
– Operating and/or ambient conditions not within the scope of the specification
– Condensation / conductive contamination
– External influences / damage
pacemaker and/or implants if they are too close.