Booksize cold-plate power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Maximum permissible DC
link capacitance
Power factor
Weight
Power loss
1) The specified values apply for 380 V
2) The specified rated power values/currents can only be achieved if direct liquid cooling is used. When mounting on an external heat sink,
derating must be applied. At a temperature of 40 °C at the interface to the power section, 80% derating occurs for
6SL3136-7TE 28-0AAx
and 70% for 6SL3136-7TE 31-2AAx
Rated duty cycles of Active Line Modules
Figure 5-6
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
6SL3136-7TE
21-6AAx
μF
20 000
cosϕ
kg
6,1
Rated duty cycles of Active Line Modules
23-6AAx
20 000
1
1
10,2
See Chapter Cabinet design and EMC
Active line modules with cold plate
5.6 Technical Specifications
25-5AAx
28-0AAx
20 000
20 000
1
1
13,8
20,3
31-2AAx
2)
2)
20 000
1
20,4
123