Front view of cabinet
Figure 2-1
Example: cabinet setup with powers ections, cold plate, and external air heat sink
In the cabinet, a fan is installed above the power sections.
To optimize usage of the external air heat sink, it is best to arrange the components in such
a way that the heat is dissipated equally over the surface of the external heat sink. This
means that, if possible, a large power section should be situated next to a smaller one. The
current carrying capacity of the DC link busbars must be taken into account here.
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
Cold plate with external air heat sinks
2.2 Example: cold plate with external air heat sink