Setting Options; Setting The System Using A Pin; Cancelling The Setting - Honeywell Galaxy Dimension Series Installer Manual

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual

Setting Options

Setting the System Using a PIN

Full Setting
Enter:
USER CODE + A
If groups are enabled and the user code has been assigned group choice then the keypad displays the set
status of the available groups:
R = Ready
F = Fault (group is unset and at least 1
zone is open)
P = Part Set
S (flashing) = selected for setting
S (steady) = already set
L =
Group is locked out and cannot be unset.
- =
Group is not available to the user
Pressing the keys for the groups toggles the
NOTE: On systems with more than eight groups, the groups are displayed in blocks of eight. Each block can
be viewed by pressing the A or B keys.
Once the required groups have been selected press the ent key to begin the setting procedure.
If groups are not enabled or the user does not have group choice, entering the user code followed by the A
key immediately starts the setting procedure.
The keypad displays the exit time countdown. At the end of the exit time, or when the setting procedure is
terminated by a FINAL or PUSH-SET zone closing, the ENTRY/EXIT HORN outputs and keypad buzz-
ers become silent for four seconds, then emit two long tones to confirm that the system is set. The message
SYSTEM IS SET appears briefly before the keypad display changes back to the normal day banner.
Part Setting
Enter:
CODE + B
This is identical to the Full Setting procedure, except the keypad display indicates that the system is being
Part Set. Only the zones which have the Part attribute enabled (refer to option 52.5 = PROGRAM
ZONE.Part), are included.

Cancelling the Setting

The full and part setting routines can be aborted by pressing the esc key (on the keypad used to begin setting)
before the system sets.
SET
SET
SET
SET
SET
A12345678
A12345678
A12345678
A12345678
A12345678
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
Groups RRSRSSSS
(Ready) to an
set flashing).
R
S (
SET
SET
SET
SET
SET
A12345678
A12345678
A12345678
A12345678
A12345678
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
Groups SSSRR---
T I M E D
T I M E D
T I M E D
T I M E D
T I M E D
PART SET
PART SET
PART SET
PART SET
PART SET
6-5
Setting the System
060
060
060
060
060
060
060
060
060
060

Hide quick links:

Advertisement

Table of Contents
loading