If the system is set, operating a Keyswitch immediately unsets the assigned groups; there is no entry time
countdown.
The Part attribute of the Keyswitch function defaults to 0 (disabled); the standard Keyswitch function full
sets the system. To part set the system using the Keyswitch, the Part attribute must be enabled.
NOTE: The operation of a Keyswitch zone can be extended to the setting and unsetting of multiple groups
by pressing the
The standard programming of the Keyswitch function requires a momentary change from 1kΩ to 2kΩ to
both set and unset the system. If the Keyswitch connected has a latching mechanism, press the
assigning the function; the display indicates 09= KEYSWITCH has been assigned. The
Keyswitch operation is as follows: 1kΩ to 2kΩ sets the system; 2kΩ to 1kΩ unsets the system.
The Keyswitch function can also be programmed to reset alarms - refer to option 51.14 =
PARAMETERS.Keyswitch Level. If the Keyswitch is assigned a sufficient type to reset the alarm condi-
tion, the alarm is cancelled and immediately reset when the Keyswitch is used to unset the system following
an alarm activation.
NOTE: The activated zones are not displayed on the keypad when a Keyswitch is used to reset the alarm.
10 Secure Final
This zone has dual functionality depending on whether the system is set or unset. When the system is setting,
set or unsetting the operation is identical to the Final zone function. When the system is unset the operation is
identical to the Security zone function.
Pressing the
key when programming a Secure Final zone doubles the entry time of the group.
Opening a Secure Final zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
The termination feature of a Secure Final zone can be extended to terminate the setting of multiple groups by
pressing the
key when assigning a group to the zone. Refer to the Star
11 Part Final
This zone has dual functionality depending on whether the system is full set or part set. When the system is full
set the zone operation is identical to the Final zone function. When the system is part set the zone operation is
identical to the Intruder zone function.
Pressing the
key when programming a Part Final zone doubles the entry time of the group.
Opening a Part Final zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
12 Part Entry
This zone has dual functionality depending on whether the system is full set or part set. When the system is full
set the zone operation is identical to the Exit zone function. When the system is part set the zone operation is
identical to the Entry zone function.
Pressing the
key when programming a Part Entry zone doubles the entry time of the group.
key when assigning a group to the zone. Refer to the Star
52 - Program Zones (cont'd)
Group Function.
6-79
Group Function.
key when