61 - Diagnostics

Engineer 2

Option 61 – Diagnostics
This option allows several diagnostic tests to be run on the system, providing valuable information on the
operational status of the Galaxy and connected modules.
The Galaxy diagnostic option performs a number of checks including:
the communication integrity between the Galaxy panel and modules on the system.
voltage measurements.
current measurements.
resistance measurements
module version checks
panel memory checks
fuse checks
This option is split into two sections: Latest and Historical.
Latest gives real time diagnostic information for the Galaxy system.
Historical allows a snapshot of the Galaxy system diagnostic status to be generated and saved.
1 Latest
The Diagnostic options are:
1. MEMORY TEST - This option forces a check of the panel memory.
2. KEYPAD COMMS - the communication level between the Galaxy panel and the keypads.
3. RIO COMMS - the voltage and version at each RIO as well as the communication level between the
Galaxy panel and the RIO.
4. PSU COMMS - the voltage at each Galaxy Dimension Power Supply Unit and the communication level
between the Galaxy panel and the SPSUs. It is identical to the RIO COMMS diagnostic with the
exception that it also indicates the current output from the SPSU, fuse status and battery status.
A number to the right of the current indicates a blown fuse:
2 = Battery fuse (F1)
3 = +12V Auxilliary 1 fuse (F4)
4 = +12V Auxilliary 2 fuse (F3).
5 = Not Used
6 = On-board Bell Fuse (F2)
A indication means low battery or a missing battery.
95%
2 13.6V 1.9A.
Galaxy Dimension Installer Manual