42 - Codes (cont'd)
STANDARD USER ACCESS
1 = Modify PIN
The PIN identifies each user to the Galaxy panel and permits the user to operate the system. The Modify
PIN option allows a PIN to be assigned to the user or an existing PIN to be modified. The PIN must be a
four, five or six digit number that is unique to the system.
NOTE: PIN size is dependent upon programming of parameter 51.66=Min Pin Size.
If a duplicate PIN is assigned, the message DUPLICATE ENTRY is displayed; the PIN is not assigned to
the user. As each digits is entered it appears on the lower line of the display. Pressing the
key erases the last
digit displayed; continued pressing of the
key will erase all of the digits. When the correct PIN has been
assigned press the ent key to accept the programming. If a MAX No. has been previously assigned the
display will prompt: delete max no. A = YES, B = NO and return to the previous menu level. When a PIN
has been assigned to a user number, a solid box ( ) is displayed on the top line of the user number details
screen.
AUTHORIZED MANAGER ACCESS
Deleting a PIN
Existing PIN entries can be completely erased by using the
key instead of a digit entry. When there is no
PIN assigned to a user number a hollow square ( ) is displayed on the top line of the user number details
screen.
Assigning Dual Codes
To program a user code as a Dual Code press the # key while the Modify PIN option is selected. The #
displays at the start of the assigned user PIN (#1314). When a PIN has been assigned as a dual code two
solid boxes (
) are displayed on the top line of the user number details screen.
NOTE: The Master manager code can not be assigned as dual.
Dual Codes Operation
Entry of a single dual code can not gain access to the menu, set or unset the system. The message NO AC-
CESS – ADDITIONAL CODE is displayed. A second dual code must be entered within 60 seconds of the
first dual code to access the menu, set or unset the system. Dual codes can be different types, the highest type
entered is granted access to the system — whether it is entered first or second.
A single entry of a dual code - without a second dual code entry within 60 seconds - is recorded in the event
log as an Illegal Code; all outputs programmed as Illegal Code are activated.
Dual Focus
If a MAX number for the same user has a # assigned the dual function only works between the PIN and the
MAX card of the same user.