Section 4: Keypads; The Galaxy Mk7 Keypad/Keyprox; General; Power Consumption - Honeywell Galaxy Dimension Series Installer Manual

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual

SECTION 4: KEYPADS

Two types of keypad can be fitted to the Galaxy Dimension: The Mk7 Keypad and the Touch Center keypad.
Both types of keypad are described in this section.

The Galaxy Mk7 Keypad/KeyProx

NOTE: References in the text to the Mk7 keypad also includes the KeyProx in this section.

General

The Galaxy Mk7 keypad/keyProx has the following features:
a 2 x 16 alphanumeric character backlit display
16 backlit push buttons as shown in figure 4-1
internal horn
power indicator LED
Lid tamper
Off-wall tamper
Address switch
RS485 serial connector

Power Consumption

The Galaxy Mk 7 keypad/keyProx requires a 12 Vd.c. supply – from the control panel or a remote power
supply. The current consumption of the keypad/keyProx is:
Nominal (backlight OFF)
Backlight ON
Maximum Alarm Current
GALAXY 264 V6.00
08:58 TUE 22 NOV
1
4
7
*
Figure 4-1. Galaxy Mk7 Keypad/KeyProx
Mode
Mk7 Keypad
Table 4-1. Keypad/KeyProx Current draw
4-1
Mk7 Keypad/KeyProx
A
2
3
B
5
6
9
ent
8
#
0
esc
Current Draw
Mk7 Keyprox
35 mA
75 mA
70 mA
90 mA
90 mA
130 mA