25 - Access Doors (cont'd)
MAX Log
The Galaxy system has a 1000 event log (GD-96, GD-264, GD-520) or 500 event log (GD-48) for the
recording the MAX activations. This log is shared by all readers on the system and operates on a first-in-first-
out basis for overwriting events when the log is filled.
To display the events in the MAX log select option 25 = ACCESS DOORS; use the A or B keys to select
the required MAX address then press the ent key. The first event that occurred on the selected MAX is
displayed along with details of the time, date and MAX number.
To view the log press the A key to move forward in time through the events or the B key to move backwards.
Press the esc key to return to the MAX address display. To view the log of another MAX, use the A or B
key to select the required address. To escape from the Access Doors option press the esc key.
Press the # key for typical additional information:
NOTE: See Appendix D for MAX Event Log Messages.
Max Events Print-Out
The MAX events can be printed out as they occur to an on-line printer. To print the MAX events ensure that
option 51.28 = PARAMETERS.On-Line Print is enabled. Select option 51.29= PARAMETERS.On-
Line Level and enter 2 to print out all system events including the MAX events or 3 to print out only the
MAX events.
NOTE: A serial printer must be connected to line one of the Galaxy panel and the printer must remain on-line
(ready to print) at all times.
Time and date
of event
MAX user number
Galaxy Dimension Installer Manual
02:25 SUN OCT
02:25 SUN OCT
02:25 SUN OCT
02:25 SUN OCT
02:25 SUN OCT
USR032 Valid
USR032 Valid
USR032 Valid
USR032 Valid
USR032 Valid
Event type
READER01 GrpA1
READER01 GrpA1
READER01 GrpA1
READER01 GrpA1
READER01 GrpA1
Reject Grp Set
Reject Grp Set
Reject Grp Set
Reject Grp Set
Reject Grp Set